How much weight can a 8x8 post support vertically - However, one rule of thumb to keep in mind while answering the question is that the answer commonly is that if a deck is properly designed, it's built to hold 50 lbs. per square foot. It's possible that it could hold much more weight than 50 lbs. per square foot. If you're allowed to span 16′ with your joists 16″ on center, but you ...

 
Standard Steel Pipe Columns - Allowable Loads; Nominal Pipe Diameter (inches) Wall Thickness (inches) Effective Length of Column (feet) ; 6 8 10 12 14 16 18 20; Allowable Concentric Loads (10 3 lb f). Aberdeen american news e edition

A triple 2×10 or 3- 2×10 header can support 7410 pounds of total weight/ load when spanning to 4 to 6 feet, 5640 pounds weight when spanning to 8 feet, 4510 pounds weight when spanning to 10 feet and can support 3760 pounds of total weight when spanning to 12 feet. Thus, a triple 2×10 or 3- 2×10 header is meant to hold up to 5640 lb weight ...A fence with 4×4 fence posts standing vertically and properly anchored in the ground can hold a weight-bearing load of approximately 10,000 pounds. Likewise, a 6×6 fence post can hold about 24,000 pounds. Steel posts can withstand 360,000 pounds of force; with vinyl withstanding 165,000 pounds. Each kind of fence post has its own purpose, and ...I understand that. But not always the case. For this application, the beam is actually being cut to a finished size and will be either 8" or 7 1/2" post kiln drying and depending on the finish treatment (planing, etc.) But for the purpose of this exercise, your math will suffice as it is assuming the actual dimension of an 8X8.The overall total weight of an oversized pergola is nearly 4,000 lbs. which would compute to be around 1,000 lbs. of undistributed weight for each beam. Simulating this would be like placing 4 extra large-sized men standing in one corner. After the weight is uniformly distributed between three other beams the PSI is considerably lessAn ~8ft long beam sits horizontally. Please just assume it is sufficiently supported and stabilized at each end. From the center of the beam hangs a ~200lb object such as a punching bag or a (living) human body. The object will not just hang statically, it will also swing. This rig is indoors only. I do not know whether the beam is a 4x4 or a 6x6.How much weight can a 2×6 joists support? The weight a 2×6 joist can support depends on factors like span, species, and load distribution. ... 2×8, and 2×10 for joists and 4×4 or 6×6 for posts. What is the strongest deck support? Steel posts or columns are among the strongest deck support options. They provide excellent load-bearing ...Are you looking to send your warmest congratulations to someone on southernliving.com? Whether it’s a friend’s new home purchase, a family member’s promotion, or a colleague’s enga...Beam Loads - Support Force Calculator Calculate beam load and supporting forces. ... You can review their privacy and cookie policy here. ... Weight kg f N lbf. Velocity m/s km/h ft/min ft/s mph knots. Pressure Pa bar mm H 2 O kg/cm 2 psi inches H 2 O. Flow m 3 /s m 3 /h US gpm cfm. 5.3.10 .The load capacity of a 3-foot #2 grade 4×4 is 17,426 pounds, and a similar 6×6 is 20,834 pounds or 16% better. However, an 8-foot 4×4 supports 6468-pounds and 2339-pounds at 14-feet, while a 6×6 is 18032 and 10550-pounds respectively - or 64% and 78% more load capacity. How much weight can a 4×4 steel post support?When an email message has been forwarded many times using Microsoft Outlook Express or Windows Mail, a number of vertical lines may be seen on the left side of the forwarded messag...2 8x8 beams join at 8x8 post. Started by rythma, October 09, 2016, 11:38:24 AM. ... The shoulder of the joint is the weight bearing surface though a little is taken up buy the tennon, if properly fitted. ... The residential code typically has a requirement for beam ends to have at least 1.5" of support. If the tenon is load bearing that can ...Products and technology that help people design and build safer, stronger homes, buildings, and communities.how much weight can a 8x8 post hold. pickleball lessons venice, fl; Rechtliches; empresas mexicanas que fracasaron al internacionalizarse; henry mountbatten, earl of medina; legacy of the dragonborn secret passage; how much weight can a 8x8 post hold.All of the formulas have the same format of a base weight given a height of 5 feet with a set weight increment added per inch over the height of 5 feet. For example, if you are a 5'10" male estimating your ideal weight with the Devine formula, you would add (2.3 × 10) kg to 50 kg to get 73 kg, or ~161 lbs.It is supported on both sides by 4". Total piece is 210". Just need an idea of weight it can hold not using this to live underneath it, it was just holding something up in the backyard shed just need an idea that soul can't hold 200 pounds 100 pounds Etc. It's also floating on cinder blocks 4 inches on each side.I want to use some over head space to store Oak boards. What I have come up with is an inverted "T" shape (so I can move wood without pulling the entire length) made with half-lapped 2x4's, glued and screwed. They will be hung from the joist with a hanger every other joist for a total of 4...The grain direction (flat or vertical) has essentially no effect on the strength. As mentioned, a piece that is 4" high with the load vertically (a 4x6 where the width is 6") is not anywhere as strong as a piece with the 6" being vertical (a 6x4 with the width being 4"). However, when sawing a piece so that the 6" face is vertical grain (or ...Decks with an above grade pier footing type should have bracing installed to prevent the post base from acting as a pivot. Bracing comes in many forms but is always used to prevent racking and increase the frames stiffness. For instance 4x4's can be installed at 45 degree angles parallel to the beam as Y or knee braces connecting the beam to ...If you multiply the area of this section 5’ x 5’, you will get 25 square feet. You can multiply this area by 55 lbs per square foot loading to come up with 1,375 lbs total load. Once you know the total load, you can use the chart below to …Hi and welcome here to DIY. You should specify if the 2x4s will be flat or vertical to the plywood. They are much stronger on the vertical orientation. Be aware that use of 1.4" plywood is inadvisable in this application. At a span between supports of 2 feet and 4 feet it will bend almost to breaking if you were to stand on it.Standard Steel Pipe Columns - Allowable Loads; Nominal Pipe Diameter (inches) Wall Thickness (inches) Effective Length of Column (feet) ; 6 8 10 12 14 16 18 20; Allowable Concentric Loads (10 3 lb f)Many of the side-mount umbrella manufacturers recommend using four 16″ patio blocks, for a total weight of over 100 lbs, to support the umbrella on windy occasions. If you already have a patio built, you may be able to pull up the blocks and insert your cross base under the blocks, then re-lay them into the patio for a flush look.I can use 4 down the length of the top board along the ceiling joist. GRK Structural Fasteners. A 1/4" lag bolt into the 1.5" side of standard S-P-F framing lumber is going to have roughly 200lbs of pull strength per inch of thread engagement, assuming your pilot hole is the right diameter and you don't over-tighten.8x8 Meet for Salesforce Integration. 8x8 Meet for Salesforce Integration Quick User Setup. 8x8 Meet Link Opens in the Browser Instead of 8x8 Work Desktop. 8x8 Work Meetings does not register Microphone and or Video hardware. Adding an 8x8 Video Meeting to an Existing Google Calendar Event. Adding an 8x8 Video Meeting When …Round wood posts are a great way to mark property lines and keep livestock contained. These posts come with a natural taper. The diameter stated is the approximate diameter of the top of the post, whereas the bottom (butt) end of the post will be larger. Posts will taper approximately 1/10 of an inch per foot or slightly more. Chromated Copper Arsenate (CCA) pressure-treated wood products have ...Section 15.3.3 of the NDS gives very specific requirements for nailing the pieces together. In addition to end, edge and row spacing guidelines, the NDS requires adjacent nails to be driven from opposite sides of the post or column. All nails must penetrate all the pieces and at least three-quarters of the way into the outermost lamination.The weight of treated wood can vary depending on factors such as the wood species, treatment level, and moisture content. On average, pressure-treated wood, commonly used for outdoor projects, can weigh around 38 to 42 pounds per cubic foot for pine, 28 to 32 pounds per cubic foot for cedar, 34 to 38 pounds per cubic foot for fir, 38 …Final Thoughts. To recap, how much weight a 4×4 can hold is mainly determined by its position. Specifically, if it’s laid vertically, it can support up to 500 lbs of centralized weight, and up to 1,000 lbs of evenly distributed weight. Standing upright, a 4×4 can support upwards of 4,300 lbs, provided there are multiple, properly spaced 4x4s.what football team does alan mcmanus support; flight 19 radio transcript; how much weight can a 8x8 post hold.Look for a Visible Foundation. Inspect the area around the bottom of each porch column for any visible foundation or base. Load-bearing columns require a stable foundation to support the weight they carry. Look for mounting plates securely screwed into the porch flooring or concrete blocks (also known as concrete piers) supporting the base of ...how much weight can a 8x8 post holdFor use with ground contact. Limited lifetime warranty. 8 in. x 8 in. x 12 ft. Can be painted or stained. No two pieces of lumber are the same. Color, grain pattern and texture will vary as well. Use #2 grade lumber when both appearance is not the most important to you project. May have wane (bark edge) on corners.A fence with 4×4 fence posts standing vertically and properly anchored in the ground can hold a weight-bearing load of approximately 10,000 pounds. Likewise, a 6×6 fence post can hold about 24,000 pounds. Steel posts can withstand 360,000 pounds of force; with vinyl withstanding 165,000 pounds. Each kind of fence post has its own purpose, and ...If you're referring to a split - log checking crack - in a vertical post, there's no repair needed unless the split has compromised a structural connection. Checking cracks in a post ( a vertical "beam") are not normally a worry at all as long as they don't run across a structural connector such as a bolt or peg. On 2022-10-14 by Mike CWe would like to show you a description here but the site won’t allow us.From the top down, a single 2 x 4 can hold up to 1,000 pounds. If too much load is put on a 2 x 4 in a construction project, it will bow before it breaks. As 2 x 4’s age, they dry and harden. Most 2 x 4’s are used as vertical wall studs; roof rafters and floor joists are generally made with 2 x 6’s or taller for more strength.how much weight can a 8x8 post hold. pickleball lessons venice, fl; Rechtliches; empresas mexicanas que fracasaron al internacionalizarse; henry mountbatten, earl of medina; legacy of the dragonborn secret passage; how much weight can a 8x8 post hold.Our next step is to check if this deflection is less than the allowable deflection for our given beam span. For that, we use the deflection criteria provided by the 2012 International Building Code, stating that beams under a combination of dead load (permanent load) and live load (loads that can vary in time) should at most have an allowable deflection equal to the span of the beam divided by ...Generally, however, plywood can support a significant amount of weight. For example, a standard 4×8 plywood sheet with a thickness of 3/4 inch can support over 2,000 pounds when properly installed with sufficient framing and support.what football team does alan mcmanus support; flight 19 radio transcript; how much weight can a 8x8 post hold.To give a rough estimate, a standard 2-inch diameter Schedule 40 PVC pipe can hold approximately 20 lbs of weight per foot when supported every 2 feet. However, a 4-inch diameter Schedule 40 PVC pipe will be able to hold LESS than 20 lbs per foot, when supported every two feet. Now, for the same 2-inch diameter pipe, if your PVC pipe is thicker ...can you bring a vape into knott's berry farm. tacacs+ advantages and disadvantages; how tall was consuelo vanderbilt; ... how much weight can a 8x8 post hold ...whatever happened to craig wasson. Doğal Süt Ürünleri Köydeki Çiftlikten Direkt Sofranıza Geliyorhow much weight can a 8x8 post hold. Posted on March 4, 2023 by . japanese stationery munich ...How much weight does a 6x6 post support vertically? Hundreds of pounds. ... How do you write 8x8 in index form? 2x6. What does 2x6 times 3x2 equal?How much weight can a vertical 4×4 hold? ... you'll probably need to use 6×6 for the support posts. For a very small pergola with only 4 to 6 feet between posts, 4×4 supports will work. Are two 2×4 stronger than one 4×4? When used vertically, 4x4s are stronger than two 2x4s. However, if you need a horizontal surface, two 2x4s will be ...Each support post should be sitting on a properly dug footing with metal standoff bases. 8x8 is surely overkill, but if you have a source, then it will handle the weight, I am sure. 6x6's would be closer to the norm for such a structure. I wanted the posts to be about 12 feet apart if possible.To find out how much weight an 8×8 post can support vertically, measure the width and the depth of the beam. Hanging 250 pounds from the middle produces a total sag of 0.07 inch, and hanging a thousand pounds will result in a sag of 0.3 inch. These values are unacceptable.Used vertically as a post, an 8’ 4×4 can support about 6,000 PSI before buckling, and even more if correctly braced. In this article, we’ll identify how much weight a 4×4 can hold …Use 1 5/8″ screws to lock the sheets to the joists, every 8″. Side-wall-frame—8×8-deer-stand. Build the side walls from 2×4 lumber. Cut the components at the right dimensions. Drill pilot holes through the plates and insert 3 1/2″ screws into the studs. You can adjust the size of the windows to suit your needs.Third, the weight capacity of a 6×6 support beam will also be determined by the number of supports it has. The more supports a beam has, the more weight it can support. This is because additional supports provide greater stability and distribute the weight. If you assume a conservative 1400psi allowable bending stress, a single 6x6 with 12 ...texdroid. • 4 yr. ago. Use 2x4s sistered together. Glued and screwed) That is stronger than a 4x4. 2x4 as a post will support about 1000 lbs, that varies a bit by species. If it is stamped "stud" it will be strong enough. Use 4 sistered pairs as your corner legs. Run 2x6 or 2x8 on edge like a header to join your legs.mm to inches calculator. If you’re looking for a quicker and more convenient solution to determining the weight of H -beams and I-beams, you can use the H-beam weight chart and I-beam weight chart provided. These charts allow you to easily check the weight of various-sized H-beams and I-beams, eliminating the need for repetitive …can you bring a vape into knott's berry farm. tacacs+ advantages and disadvantages; how tall was consuelo vanderbilt; ... how much weight can a 8x8 post hold ...lodanna king panel bed assembly instructions Call: 615-801-8220In general, a solid 2×4 can hold up to 40 pounds per linear foot. However, engineered 2x4s can be stronger, and they can hold up to 60 pounds per linear foot. The length of the 2×4 also affects its weight capacity. A longer 2×4 will be able to hold more weight than a shorter 2×4. This is because the longer 2×4 has a greater surface area to ...vertical shore is proportioned properly, (posts with length to width ratio of 25 or less) one can hear the header or sole crush against the post prior to the post starting to fail. Minimum level of lateral strength in any vertical support system should be 2% of vertical load, but 10% is desirable where aftershocks are expected. ENABLING OBJECTIVESwhen to throw away tupperware how much weight can a 8x8 post holdThe ABU is an adjustable post base designed to attach wooden posts to to existing concrete in high-capacity applications. It features a built-in 1" standoff and a slotted anchor hole in the base. ... Rough 8x8: Base 14; strap 10: 8: 7: 7 ...A 2×8 can carry between 859 and 1315 pounds vertically as a post depending on wood species, grade, and other factors. If used for a ramp, it can support up to 250 pounds per foot depending on span and other variables. On edge, it can support more than 200 PPL over 8 feet, or a center load of 370 pounds depending on all factors.How much weight can a 6×6 treated post support? A 6×6 with 12′ span can support 2000 lbs. if you assume a conservative 1400psi bending stress. If you do a good job bonding the two members together, your double 6×6 can support more than 4,000 lbs. How much weight can a 4×4 support vertically?2. Height-Dependent Weight Support. Like 4×4 posts, the height of a 6×6 post significantly influences its weight support capacity. At a height of 3 feet, a 6×6 post can manage a remarkable 20,000 pounds. This weight limit decreases as the post height increases, with a 14-foot post supporting about 10,000 pounds. 3. Optimal Weight …what is the theme of ghost by jason reynolds; Stamping Services. marine corps base quantico units; dropshipping template; mel e learning elysium; steve fiset conjointeThe typical deck posts sizes are; 4X4 (4 feet by 4 inches) 6X6 (6 feet by 6 inches) 8X8 (8 feet by 8 inches) These posts have been calculated and designed to these standard sizes so that they will appropriately handle the expected load of the deck. Moreover, the most common post types are that of 4X4 and 6X6.Don't use a 2x4 for a 10' span. It will barely support itself without sagging. If it sags it's not strong enough. Your second problem is going to be not just that it won't support a big dog but that as they swing the board has the tendency to bow, which weakens its ability to support even more. Use two 2x12s. Use 2x4 spacers between the 2x12s ...In recent years, vinegar has gained popularity as a potential aid in weight loss. While it may sound too good to be true, there is actually some scientific evidence to support this...Final Thoughts. To recap, how much weight a 4×4 can hold is mainly determined by its position. Specifically, if it’s laid vertically, it can support up to 500 lbs of centralized weight, and up to 1,000 lbs of evenly distributed weight. Standing upright, a 4×4 can support upwards of 4,300 lbs, provided there are multiple, properly spaced 4x4s.Oct 13, 2015 · How can I calculate the maximum load a rectangular horizontal wooden beam of dimensions L x H x W can safely support if the beam is adequately supported at both ends? assuming worst case - load concentrated at center; for commonly available types of wood (e.g. Spruce) Build 20x20 Deck • How much weight will a 2x6 support?-----Our main goal is creating educational content. The topic of this video has been processed in ...Despite that fact, most people know surprisingly little about how much weight a 2×4 can hold. When standing vertically, such as when it functions as a stud, a 2×4 can hold about 1,000 pounds. A 2×4 can hold up to 40 pounds or 300 pounds when laying on its edge without sagging when laying horizontally. Several factors can lower or increase a ...October 11, 2023 by GEGCalculators. A deck's weight capacity depends on factors like joist size and spacing. For a common 2×6 joist, spaced 16 inches on center, it can typically support a live load of 40-50 pounds per square foot. Larger joists and closer spacing can increase the capacity.To give you a general idea though, floor joists are sized to support 40 pounds per square foot of "live" load (moving weight) or 10 psf "dead" (stationary) load. When I framed in my loft over my shop I used 2x8's, 16 inch on center, with a max span of 11 feet. It's covered on top with 5/8" OSB glued and screwed in place and on bottom (shop ...Safe loads for wood columns. Safe loads for Wood Columns - No.1 grade Douglas fir-larch: a kip is a non-SI unit of force - it equals 1,000 pounds-force. 1 kip = 4448 Newtons (N) = 4.45 kilo Newtons (kN) = 453 kgf.To determine the size of the footing, a simple formula is used: Structural Load (lbs) / Soil Capacity (psf) = Footing Surface Area Required (sq. ft.) Here is a simple deck example: Area of the deck carried by a single post/footing: 42 sq. ft. x 50 lbs./sq. ft. = 2,100 lbs. Soil carrying capacity = 3,000 psf.The thickness of the wood determines how deep the screws, nails, or bolts can penetrate into it. This, in turn, affects the strength of the joint and the load capacity of the wood. Here are three things to consider when it comes to wood thickness and weight capacity: Thicker wood can hold more weight than thinner wood.sales insights integration user salesforce. reggie miller family pics; gaynell drexler picture; police helicopter tracker adelaideTLAR (that looks about right) methods tell me maybe a 1x2 (3/4 x 1 1/2 inches) piece of wood will probably do well up to 3 or so feet across for 50 lbs as reinforcement. :) Sadly you can't really get a good x inches of y species is good for z lbs because the tightness and orientation of the grain is also very important.The code also addresses minimums, such as how many posts should be used in a given area. In general, 8×8 posts can support approximately 900 pounds vertically. A wooden post with the right dimensions is easier to work with than a steel post. However, if you plan to use steel posts, you should consult with your local building …In general, load-bearing blocks must be able to withstand 2,500 to 3,000 psi (pounds per square inch) upon manufacture. For example, 4 x 6 lumber is not on the list, but you can simply choose 2 x 6 and double the value. Use 4 sistered pairs as your corner legs. tldr: how much weight can i put on a vertical 6x6 wood post?Sleeve gastrectomy can provide long-term weight loss. The amount of weight you lose depends on your change in lifestyle habits. It is possible to lose approximately 60%, or even more, of your excess weight within two years. In addition to weight loss, sleeve gastrectomy may improve or resolve conditions related to being overweight, including:In recent years, vinegar has gained popularity as a potential aid in weight loss. While it may sound too good to be true, there is actually some scientific evidence to support this...how much weight can a 8x8 post hold; provide for the common defense examples May 17, 2023. 1 ...The vertical pipe support was designed with industry professionals like you in mind. At Pipe Prop, we take great pride in ensuring that our products meet the needs of our customers. If you have any questions about any of the great pipe support products we offer, just contact us at 888-590-0120. We are happy to provide any assistance and ...

Another strengthening option is screwing a 1/4" thick piece of steel to the sides of the 2x8. Or rip the 2x8 into 4 pieces and glue 3 pieces of 1/4" plywood 1-1/2" tall between the pieces of 2x8. I would use baltic birch plywood because it has no voids. But the best solution may be a torsion box shelf.. Silhouette ford truck clipart

how much weight can a 8x8 post support vertically

WebThis table shows that a 4x4 pine post that is 6 ft or shorter can support a load area of up to 10 ft assuming 50 lbs/ft. Deck posts must be a minimum of 44 according to the IRC but many jurisdictions require a 66 post as a standard. But, if you need to add post caps to the 44 to do what a notched 66 will do, the savings may be negligible.0.44 pounds is the weight of a one foot section of 2×2 lumber made from Sitka spruce. Step 6 : Multiply the weight of the one foot section by the length of the board. If your 2×2 is 12 feet long, multiply 12 by 0.44 to get 5.28 pounds. And there you go, a 12-foot Sitka spruce 2×2 weighs 5.28 pounds.7 Day Customer Support. Live Chat 1-800-537-9910. Vince Gironda Part 2: 8x8 System For Mass And Leanness ... (use added weight if you can get 20reps) ... Vince suggested to find your 8 rep max in an exercise and then begin with 40% of THAT weight for 8x8. There's a TON of similar articles out there by the "more hardcore than you" lifters who ...Conclusion. The distance an LVL beam can span depends on a plethora of factors. Some manufacturers limit their beams to 60' due to transportation issues, while others have the capability to manufacture beams up to 80' long. So, the longest unsupported span possible using LVL would be 80-feet.October 1, 2023 by GEGCalculators. Steel gate post size varies based on the width and weight of the gate. For smaller gates up to 4 feet wide, 2×2 or 2.5×2.5-inch posts are suitable. Gates between 4 to 8 feet often require 2.5×2.5 or 3×3-inch posts. Larger gates from 8 to 16 feet may need 3×3 to 6×6-inch posts or larger, depending on ...Directions: Select wood species and grade (or enter values for modulus of elasticity, E, and allowable stress, F c, after setting "Species" for "Other"), wet service conditions, duration …This week we learned some harsh truths, saw some successful weight loss, boiled down building wealth, and found the programming jobs that pay the most. Here's a look back. This wee...There will actually be 4 2x2s making up the shelf and it needs to hold about 200 lbs but to be safe I'm assuming it needs to hold up 300. If you go forward with a 2x2" frame, invest in a mop and bucket too. IMO 2x2" pine isn't strong enough for that load.Codes have long required that all plies of a built up beam must bear on the post, so naturally a 4x4 (at only 3 1/2-in. wide) can only carry a three inch wide two-ply beam. Thus, the area of deck that can be supported by a 4x4 post is limited to two-ply beam spans. The 2018 height reduction recognizes proprietary post-to-beam connection ...Each 2x6 yellow pine joist, on 24 inch centers (easier math) could span 7 foot 7 inches. 40PSF is PLENTY of stiffness to sleep on. It's enough to stand on, which means you are putting most of your weight on 1-2 joists, not spreading it out over 3. It's in fact, enough to jump up and down on, or have 2-3 people stand right next to each other on ...3. Time-Efficient Training. The beauty of Gironda's training plan is that you can work your entire body and cause a significant disruption in as little as 30 minutes. On average, each exercise will take 6 to 8 minutes to complete. Two movements and a warm-up would take 20 to 25 minutes. 4. Standard Steel Pipe Columns - Allowable Loads; Nominal Pipe Diameter (inches) Wall Thickness (inches) Effective Length of Column (feet) ; 6 8 10 12 14 16 18 20; Allowable Concentric Loads (10 3 lb f) The weight capacity of a 4×6 post depends on various factors such as the type of wood, the length of the post, and the distance between the posts. Generally, a 4×6 post made of Douglas fir can support up to 4400 pounds vertically. However, this weight capacity may reduce when the post is in contact with the ground, exposed to moisture, or has ...Standard Steel Pipe Columns - Allowable Loads; Nominal Pipe Diameter (inches) Wall Thickness (inches) Effective Length of Column (feet) ; 6 8 10 12 14 16 18 20; Allowable Concentric Loads (10 3 lb f)So, a 6×6 is significantly stronger than a 4×4 in comparable situations. Optimally, a 6×6 DF (interior north) spanning 8 feet will support a center load of almost 4740 pounds and about 1180 pounds per foot if the load is uniform. Using DF-SS as a 2-foot post it has an axial compression load capacity of 34,461 pounds, at 4 feet, the load ...A lot of weight can be applied to a vertical post and support it. It is making the connections, that is the business. ... so I might take at least the ground posts up to 8x8. Whether the rest of the posts need to be bigger depends on how big my ridge beam ends up needing to be. ... 2500 lbs. or you can say that the mid-post support 10 x5x50lbs ...The 2x4 wall can handle around 1000 pounds vertically. But you put the limit to the test meaning you are probably breaking the wall before reaching 1000 pounds. Use a joint or two, a stud wall helps, or doubling the layer could help, anything to reinforce the wall if the main concerns are the wall breaking out because abused by children.HVAC Contractors- use pipe supports in attics and on roofs for proper flow drainage. Holds up to 8,000 Pounds. We have tested the pipe supports to determine exactly how much weight they can bear. Depending on which product you purchase, the pipe support can safely hold anywhere from 1,745 pounds to over 8,000 pounds. Seems to me you're trying to talk yourself into a full span of twenty feet or more. An 8x8 (even with no load) would sag under its own weight at that distance. Stop agonizing over it and add a mid-span post. Any professional carpenter will tell you the same thing. From contributor A: A 6 x 8 will span 12' for flooring. .